Barrier Isolators for Pharmaceutical Compounding Pharmacy Isolator Chambers for Compounding Sterile and Chemotherapy Preparations
    Barrier Isolators that Meet USP Chapter 797 Compliance
    for Pharmaceutical Compounding Applications
HOME       BARRIER ISOLATORS       USP 797 COMPLIANCE       ABOUT OUR COMPANY       CONTACT US

   BARRIER ISOLATORS
   » Intro to Barrier Isolators
   » A2 Barrier Isolator
   » A2 Isolator Benefits
   » Product Specification
   » Technical Data
   » Validation & QC Testing
   » Easy Change Cuff Ring
   » Options & Accessories
   » FAQs
   » Request a Quote


Request a Quote
   USP CHAPTER 797
   » Intro to USP 797
   » Risk Level Assessment
   » Gap Analysis
   » USP 797 Compliance
   » Sterile Compounding
   » Cleanroom Alternatives


   INNOVATIVE TECHNOLOGY
   » About Our Company
   » Industry Leaders
   » Customer Service

Home > A2 Pharmacy Isolator > Specifications

A2 Pharmacy Isolator - Specifications


Specifications

  • EC GMP Grade A (equivalent to ISO Class 5)air environment quality
  • Negative or Positive Pressure
  • Integrated visual and audible alarm unit
  • 3mm stainless steel grade 316 throughout
  • Glove port breach velocity of 0.7m/sec for negative pressure isolators.
  • Timed interlocks on all transfer chamber
  • Integral light units
  • 200mm diameter glove ports as standard
  • Test points for monitoring and validation
  • Safe to change exhaust filters
  • Internal electrical connections

Service Requirements

  • 110 VAC 13A single phase electrical supply
  • External air extraction system capable of extracting 106m /hr per module (non-recirculating units only)

Options

  • 250mm diameter glove ports
  • Glove Leak Tester
  • Recirculating (integral fan unit) version
  • Extract fan unit
  • Alternative electrical specification (e.g. 110v)

A2 Barrier Isolator


Learn More..
About how you can benefit from the ease, reliability & safety of the A2 Pharmacy Isolator to meet USP 797 compliance requirements.

Phone:
978-462-4415

Fax:
978-462-3338

Email:
Contact Us

Online:
Request Information
797 Compliance News
ARTICLE
What is a "compounded sterile preparation" according to USP Chapter 797?

ARTICLE
A2 Barrier Isolators as an Alternative to a Cleanroom.

ARTICLE
Using Barrier Isolators for Sterile Compounding: Meeting the new USP Chapter 797 and NIOSH environmental recommendations.

ARTICLE
Do I need a cleanroom like those used in a manufacturing environment?

ARTICLE
Innovative Technology's A2 Pharmacy Isolator meets Compliance with USP Chapter <797>.

WHITE PAPER
Use of Barrier Isolators in Compounding Sterile Preparations in Healthcare facilities.


© Innovative Technology, Inc. · 2 New Pasture Road · Newburyport · MA · 01950 · USA
Phone: 978 462-4415 · Fax: 978 462-3338 · Email: A2@gloveboxes.com

Barrier Isolators | USP 797 Compliance | Innovative Technology | Contact Us